Bias And Gain For Torque (Magnetic Flux) And Set Voltage (Current) - Mitsubishi Electric 800 Series Instruction Manual

600v class specification inverter
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

5.12.6
Bias and gain for torque (magnetic flux) and set
voltage (current)
The magnitude (slope) of the torque can be set as desired in relation to the torque setting signal (0 to 5 VDC, 0 to 10
VDC, or 4 to 20 mA).
Use Pr.73 Analog input selection or Pr.267 Terminal 4 input selection to switch among input 0 to 5 VDC, 0 to 10 V,
and 4 to 20 mA. (Refer to
Pr.
919
Terminal 1 bias command (torque)
T110
919
Terminal 1 bias (torque)
T111
920
Terminal 1 gain command (torque)
T112
920
Terminal 1 gain (torque)
T113
932
Terminal 4 bias command (torque)
T410
932
Terminal 4 bias (torque)
T411
933
Terminal 4 gain command (torque)
T412
933
Terminal 4 gain (torque)
T413
241
Analog input display unit
M043
switchover
Changing the function of analog input terminal
• The initial value for terminal 1 used as analog input is set to speed setting auxiliary (speed limit auxiliary), and terminal 4 is
set to speed command (speed limit). To use the analog input terminal as torque command, torque limit, or magnetic flux
command, set Pr.868 Terminal 1 function assignment, Pr.858 Terminal 4 function assignment to change the function.
(Refer to
page
397.)
The magnetic flux command is valid under vector control only.
Sensorless
Sensorless
Sensorless Vector
page
393.)
Initial
Name
value
0%
0%
150%
100%
0%
20%
150%
100%
0
(T) Multi-Function Input Terminal Parameters
Vector
Vector
PM
PM
PM
Setting
range
Set the torque (magnetic flux) of the bias side of
0 to 400%
terminal 1 input.
Set the converted % on bias side voltage of terminal 1
0 to 300%
input.
Set the torque (magnetic flux) of the gain (maximum) of
0 to 400%
terminal 1 input.
Set the converted % on the gain side voltage of terminal
0 to 300%
1 input.
Set the torque (magnetic flux) of the bias side of
0 to 400%
terminal 4 input.
Set the converted % on the bias side current (voltage)
0 to 300%
of terminal 4 input.
Set the torque (magnetic flux) of the gain (maximum) of
0 to 400%
terminal 4 input.
Set the converted % on gain side current (voltage) of
0 to 300%
terminal 4 input.
0
% display
Select the unit for analog input display.
1
V/mA display
Description
407
PARAMETERS
5
GROUP
T