[SENSe:]CAPacitance:RANGe:AUTO

[SENSe:]CAPacitance:RANGe:AUTO

Syntax
[SENSe:]CAPacitance:RANGe:AUTO <mode>
This command disables or enables autoranging for capacitance measurements.
Autoranging is convenient because the instrument automatically selects the
range for each measurement based on the input signal detected.
[SENSe:]CAPacitance:RANGe:AUTO?
This query returns a boolean value that represents the capacitance
autoranging setting: 0 or 1
Parameter
auto
Remarks
• Autorange thresholds:
• With autoranging enabled, the instrument selects the appropriate range
• Selecting a discrete range (see
• The instrument enables autoranging after a Factory Reset (*RST
• For measuring capacitance values greater than 1 mF, a delayed response
228
Item
Type
Boolean
Down range at: <10% of range
Up range at: >120% of range
based on the input signal detected.
page 226) will disable autoranging.
command).
should be expected from the front panel display. For remote interface
operation, increase the SCPI query timeout value. (Typically > 10000 ms.)
Range of values
0|1|OFF|ON
"[SENSe:]CAPacitance:RANGe[:UPPer]"
Default value
1