BRP Evinrude E-Tec Series Service Manual page 314

115,150,175,200 hp, 60 v models
Hide thumbs Also See for Evinrude E-Tec Series:
Table of Contents

Advertisement

GEARCASE
WATER PUMP
Assembly
Apply a drop of Adhesive 847 in the seal ring
groove at each of the four ribs.
Do not allow any adhesive to get
IMPORTANT:
into the air bleed groove in the impeller housing. If
this groove is blocked by adhesive, the pump will
lose its prime and will not pump water.
2
1. Seal ring groove
2. Ribs
3. Air bleed groove
Install the O-ring in groove in the impeller housing.
1. O-ring
Lightly coat the exterior of the impeller cup with
Gasket Sealing Compound. Install the cup in the
impeller housing.
312
Install the water tube grommet with the inside
taper facing up.
1
1. Water tube grommet
Install the impeller housing cover and torque two
screws to 24 to 36 in. lbs. (2.7 to 4.1 N·m).
3
Apply Adhesive 847 to flat side of the impeller
housing grommet. Install the grommet, flat side
down.
2311
DR1185
1
1. Impeller housing cover
2. Impeller housing grommet
Lightly coat the liner with Triple-Guard grease.
With a counterclockwise rotation, install the impel-
ler into the liner with the slot for the impeller cam
34814
facing out.
1
32000
1
2
32001

Advertisement

Table of Contents
loading