BRP Evinrude E-Tec Series Service Manual page 293

115,150,175,200 hp, 60 v models
Hide thumbs Also See for Evinrude E-Tec Series:
Table of Contents

Advertisement

Clean and degrease the adapter housing and
outer exhaust housing mating surfaces with
Cleaning Solvent. Apply Gel-Seal II sealant to the
adapter flange of the exhaust housing.
Place the adapter/inner exhaust housing into the
exhaust housing. Guide the water tube through
the hole in the outer housing.
On V4 models, be sure that
IMPORTANT:
exhaust valve linkage is oriented as shown.
Apply Triple-Guard grease to threads of adapter
retaining screws. Tighten two forward screws to
216 to 240 in. lbs. (24.5 to 27 N·m) and rear screw
to 60 to 84 in. lbs. (7 to 9.5 N·m).
1
1. Adapter retaining screws
If removed, coat the lower mounts with soapy
13692
water and press into the exhaust housing with the
"OUT" mark facing outward.
Position the mount covers. Install washers and
screws, and torque to 156 to 180 in. lbs. (18 to 20
N·m).
005218
MIDSECTION
EXHAUST HOUSING
1
005205
23033
32579
291
11

Advertisement

Table of Contents