Oil Control
Oil Injection Ratio
(Used with XD100 oil only)
Evinrude E-TEC outboards can be programmed
to run a reduced oiling rate. This feature should
only be used with Evinrude/Johnson XD100 oil.
1. Oil control setting
CAUTION
Running an Evinrude E-TEC outboard on
other grades of oil while set to the XD100
oil ratio will result in increased engine
wear and shortened outboard life.
Powerhead Break-In
Use the diagnostic software to initiate break-in oil-
ing. Break-in is a predetermined oiling program
that runs for two hours of outboard operation,
above 2000 RPM.
1
1. Break-in oil setting
ENGINE MANAGEMENT MODULE (EMM)
IMPORTANT:
rebuilt powerheads.
Timing Verification
Use the Ignition Timing screen of the diagnostic
software to check and adjust EMM timing. EMM
timing must be synchronized to crankshaft posi-
tion.
Refer to TIMING ADJUSTMENTS on p. 157.
1
005140
Perform timing verification after any of the follow-
ing procedures:
Powerhead replacement
•
Crankshaft replacement
•
Flywheel removal or replacement
•
CPS replacement
•
EMM replacement
•
EMM software replacement
•
IMPORTANT:
set and the outboard reaches operating tempera-
ture before timing verification is performed.
005140
EMM DIAGNOSTICS
Initiate Break-in programming for
Make sure the timing pointer is
4
005148
109