Oil Injection Pump

Removal
Disconnect the battery cables at the battery.
Remove engine cover and air silencer.
Remove the oil supply hose from the fitting (inlet)
of the oil injection pump.
Disconnect the electrical connector.
Make sure oil distribution hose
IMPORTANT:
routings are noted before proceeding with disas-
sembly. Center hose from primary oil manifold
connects to oil to inlet of rear oil manifold. This
hose has a 0.160 in. I.D.
Remove the oil distribution hoses from the crank-
case fittings.
Remove oil injection pump bracket clamps and
screws.
1
Oil Injector-Manifold Bracket
1. Clamp
Remove the oil injection pump assembly.
The oil injection pump and mani-
IMPORTANT:
fold is an assembly and cannot be serviced as
individual components.
Installation
Route oil distribution hoses from the oil distribu-
tion manifold to the crankcase oil delivery fittings
as they were prior to removal. Refer to Oil Supply
and Distribution Diagrams – V6 on p. 206 and
Oil Supply and Distribution Diagrams – V4 on
p. 208.
Connect oil hoses to crankcase fittings and fasten
with tie straps.
1. Crankcase fitting
Connect oil hose to rear oil manifold.
1. Oil to rear manifold
Install oil pump bracket and retaining screws.
Torque small screw to 24 to 36 in. lbs. (3 to 4 N·m)
and longer screw to 96 to 120 in. lbs. (11 to 13.5
N·m).
005346
Position the oil injection pump assembly on
bracket and install 60.5 mm Oetiker clamp.
1
1. Clamp
OILING SYSTEM
OIL COMPONENT SERVICING
1
005348
1
8
005347
005346