3.3.1 IOT Image Defect Sample

This section describes some Defect Samples and the actions to be taken in case of the follow-
ing IOT problems:
IDS1 Auger Mark
IDS2 Strobing (27 mm or 13.5 mm Pitch Density)
IDS3 White Streaks (Process Direction)
IDS4 Black Bands
IDS5 Toner Contamination
IDS6 Toner Splattering
IDS7 White Spots (Irregular)
IDS8 Regular Blank Areas in Process Direction (Spots, Streaks, Bands etc.)
IDS9 Regular Toner Contamination in Process Direction (Spots, Streaks, Bands etc.)
IDS10 Regular Toner Contamination in Process Direction (Side 2)
Version 1.0
WC 5022/5024

3.3.2 IIT Image Defect Sample

This section describes some Defect Samples and the actions to be taken in case of the follow-
ing IIT problems:
IDS11 Moire Due to Interference With Copy Documents
IDS12 Light Background Due to Background Suppression in Copies of Documents With
Frames
IDS13 Background Smear When Using Platen Copy With Non-Standard Documents
IDS14 Fluctuation In Background Suppression Values for Copies of Documents With
Medium Density
IDS15 Defects Related To Scan Print
IDS16 Cold Start Dew
IDS17 Static Electricity Offset [occurs after approx. 80 mm (the Heat Roll cycle)]
06/2014
3-13