- wire 103 orange, CCM1 power relay K-24 pin 1 to CCM2 Power relay K-25 pin 1
- wire 104 orange, CCM2 Power relay K-25 pin 1 to Cab Power relay K-26 pin 1
- wire 222 orange, Cab Power relay pin 1 to Time Delay module K-20 pin 30
- wire 970 white, Time Delay relay K-20 pin 30 to Fuel Pump relay K-07 pin 1
- wire 101 orange, CM harness splice to CCM3 connector X012 pin J1-4
- wire 100 orange, CM harness splice to CCM2 connector X015 pin J1-4
- wire 099 orange, CM harness splice to CCM1 connector X018 pin J1-4
- wire 097 orange, CM harness splice to display adapter (AD) harness connector X064 pin C
Locate the source of high voltage and repair.
B.
If the voltage reading is 10 - 18 volts, and the diagnostic screen is still indicating voltage in excess of
18 volts, there is an internal fault in CCM3.Reload the software for CCM3. If that does not correct the
concern, replace the module.
5.
Operate the combine while monitoring the voltage on the Universal Display Plus "DIAG" screen.
A.
If no high out of range voltage readings are seen, erase the error code and continue operation.