A Web Service connection exists for the XP7 Configuration Manager REST API server on which you
plan to register the storage system in Connection Settings > Web Service Connections on the
Administration tab.
See "Configuring Configuration Manager REST API connections on page 68" for more
information.
You have an account with Administrator user group (built-in group) permissions on the storage system.
Procedure
1. On the Administration tab, select Storage Service Settings > Configuration Manager Settings.
2. From the Configuration Manager Connection section at the top of the window, select the XP7
Configuration Manager connection to which you want to add a storage system.
3. At the top of the Local Storage System section, click Register.
4. In the Register Local Storage System dialog box, enter the following information for the storage
system:
The dialog content changes depending on the storage system model you select.
Model: Select the storage system model from the Model list.
Serial Number: Enter the storage system serial number.
SVP IP Address: Enter the storage system SVP IP Address.
RMI Port: Specify the storage system RMI port number. The default port number is 1099.
Enable SSL communication with SVP: Optionally, select the check box to enable SSL.
If this option is selected, the following item is shown:
SVP HTTPS Port: Specify the port number that SVP uses for HTTPS communication. The
default port number is 443.
Receive configuration-change notifications from the storage system: Select the check box to
receive configuration change notifications from the storage system.
NOTE: If the database of the XP7 Configuration Manager used for the search function does not
match the resource information of the storage system, service templates might not work properly.
Therefore, it is recommended that you enable Receive configuration-change notifications from
the storage system.
5. Click OK.
NOTE: If storage system information such as the IP address or port number changes, you must delete
the storage system and register it again.