Chapter 3 - Hardware Installation Wi² Extender
NOTE
Sometimes there may not be a central lobe peak because vertical alignment is too far off; only two
similar peaks for the side lobes are detected.
3.7.0.1
Adapting the Ethernet Cable for Connecting to
BreezeACCESS SU-ODU
The 55 cm Ethernet cable supplied with the unit has crossed Ethernet connections which have to be
adapted for connecting the unit to a BreezeACCESS ODU:
1
Cut the cable as close as possible to the connector that should be connected to the ODU (the end
without the service box).
2
Use a crimp tool for RJ-45 connectors to prepare the wires. Insert them into the appropriate pins
of the spare RJ-45 connector supplied with the unit and use the tool to crimp the connector.
Make sure to do the following:
Remove as small a length as possible of the external jacket. Verify that the external jacket is
well inside the sealing cover when connected to the unit, to ensure good sealing.
Pull back the shield drain wire before inserting the cable into the RJ-45 connector, to ensure
a good connection with the connector's shield after crimping.
The cable should provide straight pin-to-pin connections on both ends.
required wire pair connections:
54
Figure 3-3: Ethernet Connector Pin Assignments
BreezeMAX Wi² and BreezeACCESS Wi² System Manual
Figure 3-3