Alvarion BreezeACCESS Wi2 System Manual page 245

Table of Contents

Advertisement

The file Wi2Remote.bat runs in a Windows command-line session. It uses this syntax:
Remote [factory | restart | cimfile]
Specify Remote factory to factory reset the unit.
Specify Remote restart to perform a simple restart (same as powering off and back on).
The cimfile option is used only by technical support personnel for loading special firmware
files.
To perform a factory reset, follow this procedure:
1
Disconnect any cable from the AP.
2
Disconnect power from the PoE injector.
3
Configure your computer's LAN port with a static IP address of 192.168.1.2 and a subnet
mask of 255.255.255.0.
4
Use a crossover cable to connect your computer's LAN port to the PoE injector Data In port.
5
Connect a standard Ethernet cable from the PoE injector Data and PoE Out port to the AP.
6
Open a command line session on the computer.
7
Specify Remote factory and press Enter.
8
Power on the PoE injector. The script discovers the AP and causes the factory reset to occur.
9
Wait for two minutes for the factory reset to complete and then confirm operation by launching
the management tool in a web browser at address https://192.168.1.1.