Alvarion BreezeACCESS Wi2 System Manual page 45

Table of Contents

Advertisement

2
Expose the RJ-45 connector under the sealing cap on the Ethernet cable and connect to the
SU-ODU RJ-45 connector
Figure 2-9: Connecting the SU-ODU connector and inserting the Sealing Cap
3
Put the sealing cap back in its place. Make sure that the small protrusion on the side of the cap
fits inside the hole on the connector's protective body.
4
Connect the other end of the Ethernet cable to the SU port on the Wi² unit.
5
Verify that the O-ring supplied with the service box kit is in place, attach the service box to the
unit and tighten the top nut.
6
Use appropriate sealing material to protect the connection to the SU-ODU against moisture and
humidity. Use removable sealing material to enable future access to the connector.
NOTE
Use high quality sealing material such as Scotch® 130C Linerless Rubber Splicing Tape from 3M to
ensure IP-67 compliant protection against dust and water.
BreezeMAX Wi² and BreezeACCESS Wi² System Manual
Figure 2-8: Sealing Cap
(Figure
2-9).
groove
Installation
23