Cursor:xy - Rigol DS1000Z Series Programming Manual

Digital oscilloscope
Hide thumbs Also See for DS1000Z Series:
Table of Contents

Advertisement

RIGOL

:CURSor:XY

The :CURSor:XY commands can only be used when the horizontal timebase mode is XY.
Command List:
:CURSor:XY:AX
:CURSor:XY:BX
:CURSor:XY:AY
:CURSor:XY:BY
:CURSor:XY:AXValue?
:CURSor:XY:AYValue?
:CURSor:XY:BXValue?
:CURSor:XY:BYValue?
:CURSor:XY:AX
Syntax
:CURSor:XY:AX <x>
:CURSor:XY:AX?
Description
Set or query the horizontal position of cursor A in the XY cursor measurement mode.
Parameter
Name
<x>
Explanation
In the XY timebase mode, the horizontal and vertical positions of the cursor are defined
by the pixel coordinate of the XY display area. The pixel coordinate of the screen ranges
from (0,0) to (400,400). Wherein, (0,0) is located at the right top corner and (400,400) is
located at the left bottom corner. The horizontal and vertical pixel ranges are both from 0
to 400.
Return
The query returns an integer between 5 and 394.
Format
Example
:CURSor:XY:AX 200
:CURSor:XY:BX
Syntax
:CURSor:XY:BX <x>
:CURSor:XY:BX?
Description
Set or query the horizontal position of cursor B in the XY cursor measurement mode.
Parameter
Name
<x>
Explanation
In the XY timebase mode, the horizontal and vertical positions of the cursor are defined
by the pixel coordinate of the XY display area. The pixel coordinate of the screen ranges
from (0,0) to (400,400). Wherein, (0,0) is located at the right top corner and (400,400) is
located at the left bottom corner. The horizontal and vertical pixel ranges are both from 0
to 400.
Return
The query returns an integer between 5 and 394.
Format
Example
:CURSor:XY:BX 200
2-26
Type
Range
Integer
5 to 394
Type
Range
Integer
5 to 394
Chapter 2 Command System
Default
100
Default
300
DS1000Z Programming Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds1104zDs1074zDs1104z-sDs1074z-s

Table of Contents