RIGOL

:MEASure:STATistic:DISPlay

Syntax
:MEASure:STATistic:DISPlay <bool>
:MEASure:STATistic:DISPlay?
Description
Enable or disable the statistic function, or query the status of the statistic function.
Parameter
Name
<bool>
Explanation
When the statistic function is enabled, the oscilloscope makes statistic and displays the
statistic results of at most 5 measurement items that are turned on last.
Return
The query returns 0 or 1.
Format
Example
:MEASure:STATistic:DISPlay ON
Related

:MEASure:STATistic:MODE

Commands
:MEASure:STATistic:RESet
:MEASure:STATistic:ITEM
:MEASure:ITEM
:MEASure:STATistic:MODE
Syntax
:MEASure:STATistic:MODE <mode>
:MEASure:STATistic:MODE?
Description
Set or query the statistic mode.
Parameter
Name
<mode>
Explanation
DIFFerence: select the difference mode. The statistic results contain the current
value, average value, standard deviation and counts.
EXTRemum: select the extremum mode. The statistic results contain the current
value, average value, minimum and maximum.
Sending the
When the statistic function is enabled, the oscilloscope makes statistic and displays
the statistic results of at most 5 measurement items that are turned on last.
Return
The query returns DIFF or EXTR.
Format
Example
:MEASure:STATistic:MODE DIFFerence
:MEASure:STATistic:MODE?
Related
:MEASure:STATistic:DISPlay
Commands
:MEASure:STATistic:RESet
:MEASure:STATistic:ITEM
2-60
Type
Range
Bool
{{0|OFF}|{1|ON}}
Type
Range
Discrete
{DIFFerence|EXTRemum}
:MEASure:STATistic:DISPlay
Chapter 2 Command System
command can enable the statistic function.
/*Select the difference mode*/
/*The query returns DIFF*/
DS1000Z Programming Guide
Default
0|OFF
Default
EXTRemum

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds1104zDs1074zDs1104z-sDs1074z-s

Table of Contents