Chapter 2 Command System
Other Parameters
Area
:
The area of the whole waveform within the screen and the unit is voltage-second. The area meadured
above the zero reference (namely the vertical offset) is positive and the area measured below the zero
reference is negative. The area measured is the algebraic sum of the area of the whole waveform
within the screen.
Period Area
:
The area of the first period of the waveform on the screen and the unit is voltage-second. The area
above the zero reference (namely the vertical offset) is positive and the area below the zero reference
is negative. The area measured is the algeraic sum of the area of the waveform within the whole period.
Note that when the waveform on the screen is less than a period, the period area measured is 0.
Command List:
:MEASure:SOURce
:MEASure:COUNter:SOURce
:MEASure:COUNter:VALue?
:MEASure:CLEar
:MEASure:RECover
:MEASure:ADISplay
:MEASure:AMSource
:MEASure:SETup:MAX
:MEASure:SETup:MID
:MEASure:SETup:MIN
:MEASure:SETup:PSA
:MEASure:SETup:PSB
:MEASure:SETup:DSA
:MEASure:SETup:DSB
:MEASure:STATistic:DISPlay
:MEASure:STATistic:MODE
:MEASure:STATistic:RESet
:MEASure:STATistic:ITEM
:MEASure:ITEM