Math:option:threshold1; Math:option:threshold2 - Rigol DS1000Z Series Programming Manual

Digital oscilloscope
Hide thumbs Also See for DS1000Z Series:
Table of Contents

Advertisement

Chapter 2 Command System

:MATH:OPTion:THReshold1

Syntax
:MATH:OPTion:THReshold1 <thre>
:MATH:OPTion:THReshold1?
Description
Set or query the threshold level of source A in the logic operation. The default unit is V.
Parameter
Name
<thre>
Explanation
Return
The query returns the threshold level in scientific notation.
Format
Example
:MATH:OPTion:THReshold1 0.8
:MATH:OPTion:THReshold1?
Related
:CHANnel<n>:SCALe
Commands
:CHANnel<n>:OFFSet

:MATH:OPTion:THReshold2

Syntax
:MATH:OPTion:THReshold2 <thre>
:MATH:OPTion:THReshold2?
Description
Set or query the threshold level of source B in the logic operation. The default unit is V.
Parameter
Name
<thre>
Explanation
Return
The query returns the threshold level in scientific notation.
Format
Example
:MATH:OPTion:THReshold2 0.5
Related
:CHANnel<n>:SCALe
Commands
:CHANnel<n>:OFFSet
DS1000Z Programming Guide
Type
Real
This command is only applicable to the logic operations (A&&B, A||B, A^B and !A).
Vertical Scale refers to the vertical scale of source A
Vetical Offset refers to the vertical offset of source A
The step is Vertical Scale/25
Type
Real
This command is only applicable to the logic operations (A&&B, A||B, A^B and !A).
Vertical Scale refers to the vertical scale of source B
Vetical Offset refers to the vertical offset of source B
The step is Vertical Scale/25
Range
(-4*Vertical Scale – Vertical Offset) to
(4*Vertical Scale – Vertical Offset)
/*Set the threshold level to 800mV*/
/*The query returns 8.000000e-01*/
Range
(-4*Vertical Scale–Vertical Offset) to
(4*Vertical Scale–Vertical Offset)