Rigol DS1000Z Series Programming Manual page 141

Digital oscilloscope
Hide thumbs Also See for DS1000Z Series:
Table of Contents

Advertisement

Chapter 2 Command System
:TRIGger:IIC:ADDRess
Syntax
:TRIGger:IIC:ADDRess <adr>
:TRIGger:IIC:ADDRess?
Description
Set or query the address when the trigger condition is ADDRess or ADATa in I2C
trigger.
Parameter
Name
<adr>
Explanation
In 2
Return Format
The query returns an integer.
Example
:TRIGger:IIC:ADDRess 100
Related
:TRIGger:IIC:AWIDth
Command
:TRIGger:IIC:DIRection
Syntax
:TRIGger:IIC:DIRection <dir>
:TRIGger:IIC:DIRection?
Description
Set or query the data direction when the trigger condition is ADDRess or ADATa in I2C
trigger.
Parameter
Name
<dir>
Explanation
This command is invalid when the address bits is 8.
Return Format
The query returns READ, WRIT or RWR.
Example
:TRIGger:IIC:DIRection RWRite
Related
:TRIGger:IIC:AWIDth
Command
:TRIGger:IIC:DATA
Syntax
:TRIGger:IIC:DATA <data>
:TRIGger:IIC:DATA?
Description
Set or query the data when the trigger condition is DATA or ADATa in I2C trigger.
Parameter
Name
<data>
Explanation
The range of <data> is related to the byte length. The maximum byte length is 5,
namely 40 bits binary data. Thus, the range of <data> is from 0 to 2
Return Format
The query returns an integer.
Example
:TRIGger:IIC:DATA 64
Related
:TRIGger:IIC:WHEN
Command
DS1000Z Programming Guide
Type
Integer
n
– 1, n is the current address bits.
Type
Range
Discrete
{READ|WRITe|RWRite}
Type
Integer
Range
n
0 to 2
– 1: 0 to 127, 0 to 255 or 0 to 1023
Range
40
0 to 2
- 1
RIGOL
Default
1
Default
READ
Default
82
40
– 1.
2-127

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds1104zDs1074zDs1104z-sDs1074z-s

Table of Contents