RIGOL
:TRIGger:SPI:WHEN
Syntax
:TRIGger:SPI:WHEN <trig_type>
:TRIGger:SPI:WHEN?
Description
Set or query the trigger condition in SPI trigger.
Parameter
Name
<trig_type>
Explanation
When the trigger condition is set to TIMeout, you can use the
command to set the timeout value.
Return
The query returns CS or TIM.
Format
Example
:TRIGger:SPI:WHEN TIMeout
Related
:TRIGger:SPI:TIMeout
Command
:TRIGger:SPI:WIDTh
Syntax
:TRIGger:SPI:WIDTh <width>
:TRIGger:SPI:WIDTh?
Description
Set or query the data bits of the SDA channel in SPI trigger.
Parameter
Name
<width>
Return
The query returns an integer.
Format
Example
:TRIGger:SPI:WIDTh 10 /*Set the data bits of the SDA channel to 10*/
Related
:TRIGger:SPI:DATA
Command
:TRIGger:SPI:DATA
Syntax
:TRIGger:SPI:DATA <data>
:TRIGger:SPI:DATA?
Description
Set or query the data in SPI trigger.
Parameter
Name
<data>
Explanation
The range of <data> is related to the data bits. The maximum data bits is 32. Thus, the
range of <data> is from 0 to 2
Return
The query returns an integer.
Format
Example
:TRIGger:SPI:DATA 5
Related
:TRIGger:SPI:WIDTh
Command
2-130
Type
Range
Discrete
{CS|TIMeout}
/*Set the trigger condition to TIMeout*/
Type
Range
Integer
4 to 32
Type
Range
32
Integer
0 to 2
-1
32
-1.
/*Set the data to 5*/
Chapter 2 Command System
Default
CS
:TRIGger:SPI:TIMeout
Default
8
Default
0