4 POSITIONING DEDICATED SIGNALS
(16) Manual pulse generator enable flag (M2051 to M2053)
This flag set the enabled or disabled state for positioning with the pulse input
from the manual pulse generators connected to P1 to P3
• ON ........ Positioning control is executed by the input from the manual pulse
generators.
• OFF ...... Positioning control cannot be executed by the manual pulse
generators because of the input from the manual pulse generators is
ignored.
Default value is invalid (OFF).
REMARK
(Note) : Refer to the " Q173D(S)CPU/Q172D(S)CPU Motion controller User's
Manual" for P1 to P3 connector of the Q173DPX.
(17) Operation cycle over flag (M2054) ............................. Status signal
This flag turns on when the time concerning motion operation exceeds the
operation cycle of the Motion CPU setting (SD523). Perform the following
operation, in making it turn off.
• Turn the power supply of the Multiple CPU system on to off
• Reset the Multiple CPU system
• Reset using the user program
[Error measures]
1) Change the operation cycle into a large value in the system setting.
2) The number of instruction completions of an event task or NMI task in
the Motion SFC program.
4 - 46
..................Command signal
(Note)
of the Q173DPX.