Mitsubishi Electric Q Series Programming Manual page 52

Motion controller sv22 virtual mode
Hide thumbs Also See for Q Series:
Table of Contents

Advertisement

4 POSITIONING DEDICATED SIGNALS
Device No.
M3072
PLC ready flag
M3073
Speed switching point specified flag
M3074
All axes servo ON command
Real mode/virtual mode switching request
M3075
(SV22)
JOG operation simultaneous start
M3076
command
M3077
Manual pulse generator 1 enable flag
M3078
Manual pulse generator 2 enable flag
M3079
Manual pulse generator 3 enable flag
M3080
Motion error history clear request flag
M3081
Unusable
to
(55 points)
M3135
(Note-1): The state of a device is not in agreement when the device of a remark column is turned ON/OFF directly. In addition,
when the request from a data register and the request from the above device are performed simultaneously, the request
from the above device becomes effective.
(Note-2): It can also be ordered the device of a remark column.
(Note-3): Do not use it as a user device. It can be used as a device that performs automatic refresh because of area for the
reserve of command signal.
(9) Common device list (Command signal)
Signal name
(Note-3)
POINT
The device of a remark column turns ON by OFF to ON of the above device, and
turns OFF by ON to OFF of the above device.
The command signal cannot be turned ON/OFF by the PLC CPU in the automatic
refresh because the statuses and commands are mixed together in M2000 to
M2053. Use the above devices in the case.
And, it can also be turned ON/OFF by the data register. (Refer to Section 4.2.8)
Refresh cycle
Fetch cycle
Main cycle
At start
Operation cycle
At virtual mode
transition
Main cycle
4 - 13
Remark
Signal direction
(Note-1), (Note-2)
M2000
M2040
M2042
M2043
Command
signal
M2048
M2051
M2052
M2053
M2035

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents