4 POSITIONING DEDICATED SIGNALS

4.4 Special Relays (SM)

There are 2256 special relay points of SM0 to SM2255 in the Motion CPU.
Of these, devices in a Table 4.4 are used for the positioning control.
The special relay list used for the positioning control is shown below.
(Refer to " Q173D(S)CPU/Q172D(S)CPU Motion controller Programming Manual
(COMMON)" for the application of special relays except below.)
Device No.
SM500
PCPU READY complete flag
SM501
TEST mode ON flag
SM502
External forced stop input flag
SM503
Digital oscilloscope executing flag
SM506
External forced stop input ON latch flag
SM508
Amplifier-less operation status flag
SM510
TEST mode request error flag
SM512
Motion CPU WDT error flag
SM513
Manual pulse generator axis setting error flag
SM516
Servo program setting error flag
(1) PCPU READY complete flag (SM500) ......................... Status signal
This flag is used as judgement of the normal or abnormal in the Motion CPU side
using the sequence program.
(a) At leading edge of PLC ready flag (M2000), the fixed parameters, servo
parameters and limit switch output data are checked, and if error is not
detected, this flag turns on.
The servo parameters are written to the servo amplifiers and the M-codes
are cleared.
(b) This flag turns off when the PLC ready flag (M2000) turns off.
PLC ready flag
(M2000)
PCPU READY
complete flag
(SM500)
Ver.!
: Refer to Section 1.4 for the software version that supports this function.
Table 4.4 Special relay list
Signal name
Ver.!
4 - 80
Refresh cycle
Fetch cycle
Main cycle
Operation cycle
Main cycle
Operation cycle
Main cycle
t
The servo parameters are
written to the servo amplifiers
and the M-codes are cleared.
Signal type
Status signal