8 OUTPUT MODULE
(5) Cam data table
(a) This device is used to set each point stroke ratio (when the stroke amount is
divided into 32767 divisions) in the set resolution.
32767
Stroke
amount
Lower stroke
limit value
(Lower dead
point)
(b) The cam data table is automatically created by creating the cam curve using
MT Developer2.
The cam curves which can be used in the Motion CPU are shown in Section
8.4.4.
Output value
(Address)
(0)
0
8 - 28
Cam curve
Stroke ratio
1 cycle
t