Tcp/Udp/Ip Parameter - Mitsubishi Electric MELSEC Q Series User Manual

Ethernet/ip network interface module for programmable controller
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

3
SPECIFICATIONS
3.3.3

TCP/UDP/IP parameter

Parameters such as IP address of the EtherNet/IP module are stored in this area.
TCP/UDP/IP parameters can be set in Utility Package.
This area is used when setting TCP/UDP/IP parameters by sequence program.
The parameters set in this area are reflected into the EtherNet/IP module by either of the
following signals.
(1) DHCP setting (Un\G16385)
Select "Use" or "Not use" for the DHCP client function of the EtherNet/IP module.
For details of the DHCP client function, refer to the following.
(2) IP Address (Un\G16386 to Un\G16387)
Set the IP address of the EtherNet/IP module.
IP address data are stored in order from the least significant word.
When the IP address is "192.168.0.1"
Un\G16386
Un\G16387
• When saving parameters to flash ROM
Flash ROM access request (Y06)
(
Section 3.2.4 Flash ROM access request (Y06)/Access completion
(X06)/Access error completion (X07))
• When not saving parameters to flash ROM
TCP/UDP/IP parameter change request (Y08)
(
Section 3.2.5 TCP/UDP/IP parameter change request (Y08), TCP/UDP/IP
parameter change completion (X08))
• 0: Not use
• 1: Use
Section 4.5 DHCP Client Function
Table 3.11 IP Address "192.168.0.1"
Address
Stored value
0001
3rd and 4th octet of the Ethernet address
H
C0A8
1st and 2nd octet of the Ethernet address
H
3.3 Buffer Memory
3.3.3 TCP/UDP/IP parameter
1
2
3
4
5
6
7
8
3
- 19