UTILITY PACKAGE (SW1DNC-EIPUTL-E)
Item
Setting Area
Setting Item
Transfer Direction
Nic1/Nic2/Nic3/Nic4
Size
Refresh Device
(Start Device)
Refresh Device
(End Device)
(2) Adding settings
Set the device and the start address in "Refresh Device (Start Device)" of the
"Refresh Parameter" window and click the
(3) Deleting the settings
Delete the setting of "Refresh Device (Start Device)" on the "Refresh Parameter"
window and click the
Table 7.24 Description of the "Refresh Parameter" window
Displays the data items to refresh.
(Data Area)
Set the refresh target device for send/receive data of Tag communication for each
input/output area.
The following are setting items and their buffer memory.
•Class1 Input Area (Un\G0 to Un\G4095)
•Class3/UCMM Input Area (Un\G4096 to Un\G8191)
•Class1 Output Area (Un\G8192 to Un\G12287)
•Class3/UCMM Output Area (Un\G12288 to Un\G16383)
When setting the refresh target device for each tag, set it in "Refresh Device" of Tag
Parameter. (
Section 7.9.2 (2) Display and settings of the "Producer Tag" window,
Section 7.9.3 (2) Display and settings of the "Consumer Tag" window)
However, "Data Area" on this window and "Refresh Device" on Tag Parameter window
cannot be set simultaneously.
(Extension Data Area)
Set the refresh target of the transmitted and received data of Tag communications for
each Extension Input Area or Extension Output Area.
The Extension Data Area data are not stored in the buffer memory.
(Status Area)
Set the refresh target device for items such as error codes of own station.
The following are setting items and their buffer memory.
•Own station error status (Un\G27264)
•Communication Status (Class1)(Un\G27136 to Un\G27151)
•Class1 Diagnostics Information (Un\G27392 to Un\G27647)
•Communication Status (Class3/UCMM)(Un\G27184 to Un\G27199)
•Class3/UCMM Diagnostics Information (Un\G27648 to Un\G27903)
Displays the directions of data flow.
Configure the auto refresh settings for each EtherNet/IP module.
Only the Nic No. that has been configured in the "Add Own Nic" window can be
configured.
Displays or sets the refresh size of the setting items.
Enter the QCPU device to auto refresh.
•Any of the L/M/D/R/B/W/ZR can be selected.
When using the M or B bit device, set the number dividable by 16 (Example: M16).
•For the device setting range, refer to the following.
Section 7.1 (2) Device ranges of auto refresh
Displays the QCPU device to auto refresh.
button.
OK
7.9 "Setting" Tab (Parameter Settings)
Description
button.
OK
7.9.7 "Refresh Parameter" window
1
2
3
4
5
6
7
8
7
- 52