4.2 Tag Communication Function
4.2.1 Class1 Tag communication
3) Timeout time applied when RPI is changed
The Timeout time value is calculated with the changed RPI.
Timeout time =
(changed RPI) (Time Out Multiplier set in Consumer Tag)
The RPI can be checked in the "Connection" window on the "Monitoring" tab of
Utility Package.
Figure 4.9 RPI checking
(c) Time required to recognize the Application Trigger request (Class1)(Un\G27008
to Un\G27023)
A maximum of 10ms is required after the Application Trigger request
(Class1)(Un\G27008 to Un\G27023) is set to on.
(d) When requesting a connection to the same Producer Tag from multiple Consumer
Tags
The connection can be made only with the type of connection (Multicast/Point to
Point) that is established first.
After that, an error occurs if a connection is requested with a different connection
type.