7
UTILITY PACKAGE (SW1DNC-EIPUTL-E)
Item
Input/
Output
Area Size
Input Area
Class1
Size
Output
Area Size
Input/
Output
Area Size
Class3/
Input Area
UCMM
Size
Output
Area Size
Label (for GX Works2) Setting
Enable
7
- 35
7.9 "Setting" Tab (Parameter Settings)
7.9.1 "Basic" window
Table 7.15 "Add Own Nic" window items (Continued)
Set the total of the extended sizes of Class1 Input Area and Class1 Output Area.
Default setting: 8192 words
Maximum data size: 16384 words
Set the extended size of Class1 Input Area.
Default setting: 4096 words
Maximum data size: 16384 words
The extended size of Class1 Output Area is displayed.
The value is automatically obtained by subtracting the size set in "Input Area Size" from the size set in
"Input/Output Area Size" of "Class1".
The total of the extended sizes of Class3/UCMM Input Area and Class3/UCMM Output Area is displayed.
The value is automatically obtained by subtracting "Input/Output Area Size" of "Class1" from the
maximum data size (16384 words).
Set the extended size of Class3/UCMM Input Area.
Default setting: 4096 words
Maximum data size: 16384 words
The extended size of the Class3/UCMM Output Area is displayed.
The value is automatically obtained by subtracting the size set in "Input Area Size" from the size set in
"Input/Output Area Size" of "Class3/UCMM".
Enable the setting of the label name in the Tag so that the label data for GX Works2 can be exported.
(
Section 7.8.1 Exporting label data for GX Works2)
Select the checkbox to enable the setting.