Precautions

(1) The number of auto refresh parameter settings
(a) The number of auto refresh parameters that can be set to a QCPU
(b) The number of auto refresh parameters that can be set to the EtherNet/IP module
Figure 7.1 How to count the number of auto refresh settings in "Refresh Parameter" window
When multiple intelligent function modules are mounted with, set parameters
within the range shown in the table below.
Table 7.1 Maximum number of auto refresh parameter settings
CPU type
Q00J/Q00/Q01CPU
Q02/Q02H/Q06H/Q12H/Q25HCPU
Q02PH/Q06PH/Q12PH/Q25PHCPU
Q00UJ/Q00U/Q01UCPU
Q02UCPU
Q03UD/Q04UDH/Q06UDH/Q10UDH/Q13UDH/Q20UDH/Q26U
DH/Q03UDE/Q04UDEH/Q06UDEH/Q10UDEH/Q13UDEH/Q20
UDEH/Q26UDEH/Q50UDEH/Q100UDEH/Q03UDV/Q04UDV/Q
06UDV/Q13UDV/Q26UDVCPU
A maximum of 255 auto refresh parameters can be set.
The displayed numbers are a total of refresh parameters set in each window
below.
Maximum number of auto
refresh parameter settings
256
1024
2048
This field is counted as one setting.
Blank fields are not counted.