7
UTILITY PACKAGE (SW1DNC-EIPUTL-E)
7.9.3

"Consumer" window

Make settings for the Consumer Tag and the auto refresh target device of the Class1 Tag
communications.
(1) Display and settings of the "Consumer" window
Item
The settings of the Class1 Tag communications are displayed.
The connected Tag count and the size of the storage area for transmitted and received data are displayed as
"Tag Counts" and "Input/Output Area Size" set in the "Add Own Nic" window of the "Basic" window.
Tag setting status list
(
Any row of a Nic No. that has not been set is displayed grey.
Tag Counts
"Number of registered Tags/number of connected Tags" is displayed.
"Number of words used/size of the storage area for transmitted and received data" of Data Area is displayed.
The number of words used is applied to "Input Area" when "Data Size" is configured in the "Consumer Tag"
Data Area
window. (
"Number of words used/size of the storage area for transmitted and received data" of Extension Data Area is
Extension Data Area
displayed.
Extension Data Area is used when the number of words used exceeds the size of "Data Area".
Figure 7.24 "Consumer" window
Table 7.18 "Consumer" window items
Section 7.9.1 (1) Display and settings of the "Add Own Nic" window)
(2) Display and settings of the "Consumer Tag" window in this section)
Description
7.9 "Setting" Tab (Parameter Settings)
7.9.3 "Consumer" window
Tag setting status list
Tag Parameter list
7
- 40
1
2
3
4
5
6
7
8