9
TROUBLESHOOTING
Error code
Error
(Hex.)
C1B6
H
C1B7
H
Extended error
C1B8
H
C1B9
H
C1BA
H
C1BB
H
C1BC
H
C2**
General error
H
9
- 19
9.4 Error Code
9.4.2 Error code list
Table 9.6 Communication error of the EtherNet/IP module (Continued)
Error detail
Redundant connection mismatch.
The following fields do not match when
attempting to establish a redundant owner
connection to the same target path.
•O
T_RPI
•O
T_connection_parameters
•T
O_RPI
•T
O_connection_parameters
•xport_type_and_trigger
No user configurable link consumer resources
are available in the producing device.
The configured consuming node No. is already in
use for a producing application.
No user configurable link consumer resources
are available in the producing device.
No link resource is available on the consuming
node, which is set in the producing application.
The network link in a path to the device is offline.
No Target application data is available.
The Target application does not have valid data
to produce for the requested connection.
No Originator application data is available.
The Originator application does not have valid
data to produce for the requested connection.
Vender-specific error.
General CIP error code.
A general CIP error code is stored in the place
where ** is shown.
Action
Find the conditions for the target device to notify
this error and take measures.
(
the manual for the target device)