TROUBLESHOOTING
Table 9.6 Communication error of the EtherNet/IP module (Continued)
Error code
Error
(Hex.)
C137
to
H
System error
C138
H
Connection
C139
information
H
acquisition error
TCP/IP interface
C13B
object attribute
H
acquisition failure
Assembly instance
C13C
H
creation failure
C13D
System error
H
C142
to
H
System error
C146
H
Duplicate IP
C147
H
address
C148
Invalid IP address
H
C149
to
H
System error
C15F
H
C160
Invalid IP address
H
Invalid connection
C161
H
type
C162
Invalid trigger
H
C163
Duplicate setting
H
Invalid receive data
C166
H
size
Invalid send data
C167
H
size
C16A
Invalid Time Out
H
C16B
Invalid tag type
H
C16C
Invalid tag name
H
C16D
Invalid data size
H
C16E
Invalid data type
H
C16F
Invalid Min_RPI
H
C170
Invalid Default_RPI
H
Max_RPI
Min_
C171
H
RPI
C173
Invalid RPI
H
C174
Invalid Time Out
H
Error detail
System error
There is no connection information available for
the specified instance.
Failed to acquire a TCP/IP interface object
attribute.
Failed to create an assembly instance.
System error
System error
The IP address is duplicated.
The IP address of the EtherNet/IP module is
invalid.
System error
Own station's or invalid IP address is set for "IP
Address" of Tag Parameter.
An option other than "Multicast" and "Point to
Point" is specified for "Connection Type" of Tag
Parameter.
An option other than "Cyclic" and "Application
Trigger" is specified for "Trigger" of Tag
Parameter.
The same tag is being created.
The specified receive data size is 251 words (501
bytes) or more.
The specified send data size is 251 words (501
bytes) or more.
The specified Time Out Multiplier is out of range.
The specified tag type is invalid
No tag name is set.
The data size is invalid.
An option other than "INT" and "DINT" is
specified for "Data Type".
The specified RPI(Min) value is outside the range
of 5 to 9999.
The RPI(Default) value is invalid.
•The specified value is outside the range of 5 to
10000.
•A value smaller than Min_RPI is set.
•A value larger than Max_RPI is set.
The specified RPI(Max) value is smaller than
RPI(Min).
The specified RPI value is outside the range of 5
to 10000.
The specified Time Out value is outside the
range of 30 to 10000.
Action
Please consult your local Mitsubishi
representative.
•Retry after a while.
•Restart the EtherNet/IP module.
•Retry after a while.
•Restart the EtherNet/IP module.
Restart the EtherNet/IP module.
Please consult your local Mitsubishi
representative.
Please consult your local Mitsubishi
representative.
Change the IP address of the EtherNet/IP module
or the other device in the same network.
Correct the IP address of the EtherNet/IP module.
Please consult your local Mitsubishi
representative.
Correct the "IP Address" setting in Tag Parameter.
Correct the "Data Type" setting in Tag Parameter.
Correct the "Trigger" setting in Tag Parameter.
Change the tag name in Tag Parameter.
Correct the "Data Size" value in Tag Parameter.
Correct the "Data Size" value in Tag Parameter.
Correct the "Time Out MultiPlier" value in Tag
Parameter.
Correct the tag type in Tag Parameter.
Set a tag name in Tag Parameter.
Correct the tag type or "Data Size" setting in Tag
Parameter.
Correct the "Data Type" setting in Tag Parameter.
Correct the "Min RPI" value in Producer Tag.
Correct the "Default RPI" value in Producer Tag.
Check and correct the "Max RPI" and "Min RPI"
values in Producer Tag.
Correct the "Data Size" value in Tag Parameter.
Correct the "Time Out MultiPlier" value in Tag
Parameter.
9.4 Error Code
9.4.2 Error code list