Danfoss VLT AutomationDrive Design Manual page 97

Hide thumbs Also See for VLT AutomationDrive:
Table of Contents

Advertisement

How to Order
To order drives with a different language package, please
contact your local sales office.
Ordering type codemodel number frame sizes A, B and C
Description
Product group
Drive series
Power rating
Phases
Mains voltage
5
5
Enclosure
RFI filter
Brake
Display
Coating PCB
Mains option
Adaptation
Adaptation
Software release 24-
Software
language
1): FC 301/ frame sizeA1 only
2) US Market only
3): A and B frames have load-sharing built-in by default
96
FC 300 Design Guide
Pos
Possible choice
1-3
FC 30x
4-6
301:FC 301
302: FC 302
8-10
0.25-75 kW
11
Three phases (T)
11-
T 2: 200-240V AC
12
T 4: 380-480V AC
T 5: 380-500V AC
T 6: 525-600V AC
T 7: 525-690V AC
13-
E20: IP20
15
E55: IP 55/NEMA Type 12
P20: IP20 (with back plate)
P21: IP21/ NEMA Type 1 (with back plate)
P55: IP55/ NEMA Type 12 (with back plate)
Z20: IP 20
1)
E66: IP 66
16-
H1: RFI filter class A1/B1
17
H2: No RFI filter, observes class A2
1)
H3: RFI filter class A1/B1
H6: RFI filter Maritime use
1)
HX: No filter (600V only)
18
B: Brake chopper included
X: No brake chopper included
1)
T: Safe Stop No brake
1)
U: Safe stop brake chopper
19
G: Graphical Local Control Panel (LCP)
N: Numerical Local Control Panel (LCP)
X: No Local Control Panel
20
C: Coated PCB
X. No coated PCB
21
X: No mains option
1: Mains disconnect
3: Mains disconnect and Fuse
5: Mains disconnect, Fuse and Load sharing
3)
7: Fuse
2)
8: Mains disconnect and Load sharing
2, 3)
A: Fuse and Load sharing
D: Load sharing
3)
22
X: Standard cable entries
O: European metric thread in cable entries
(A5, B1, B2, C1, C2 only)
23
X: No adaptation
SXXX: Latest release - standard software
27
28
X: Not used
MG.33.BD.02 - VLT
Ordering type codemodel number frame sizes D and E
Description
Product group
Drive series
Power rating
Phases
Mains voltage
Enclosure
RFI filter
Brake
Display
Coating PCB
2)
2,
Mains option
3)
Adaptation
Adaptation
Software release 24-
Software
language
1): Available for all D frames. E frames 380-480/500V only
2) Consult factory for applications requiring maritime certification
®
is a registered Danfoss trademark
Pos
Possible choice
1-3
301: FC 302
4-6
302: FC 302
8-10
37-560 kW
11
Three phases (T)
11-
T 5: 380-500V AC
12
T 7: 525-690V AC
13-
E00: IP00/Chassis
15
C00: IP00/Chassis w/ stainless steel back
channel
E0D: IP00/Chassis, D3 P37K-P75K, T7
C0D: IP00/Chassis w/ stainless steel back
channel, D3 P37K-P75K, T7
E21: IP 21/ NEMA Type 1
E54: IP 54/ NEMA Type 12
E2D: IP 21/ NEMA Type 1, D1 P37K-P75K,
T7
E5D: IP 54/ NEMA Type 12, D1 P37K-P75K,
T7
E2M: IP 21/ NEMA Type 1 with mains
shield
E5M: IP 54/ NEMA Type 12 with mains
shield
16-
H2: RFI filter, class A2 (standard)
17
1)
H4: RFI filter class A1
H6: RFI filter Maritime use
L2: Low Harmonic Drive with RFI filter,
class A2
L4: Low Harmonic Drive with RFI filter,
class A1
B2: 12-pulse drive with RFI filter, class A2
B4: 12-pulse drive with RFI filter, class A1
18
B: Brake IGBT mounted
X: No brake IGBT
R: Regeneration terminals (E frames only)
19
G: Graphical Local Control Panel LCP
N: Numerical Local Control Panel (LCP)
X: No Local Control Panel (D frames IP00
and IP 21 only)
20
C: Coated PCB
X. No coated PCB (D frames 380-480/500V
only)
21
X: No mains option
3: Mains disconnect and Fuse
5: Mains disconnect, Fuse and Load
sharing
7: Fuse
A: Fuse and Load sharing
D: Load sharing
22
X: Standard cable entries
23
X: No adaptation
Actual software
27
28
2)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt fc 300

Table of Contents