Flat Packs - Danfoss VLT AutomationDrive Design Manual

Hide thumbs Also See for VLT AutomationDrive:
Table of Contents

Advertisement

How to Order

5.2.7 Flat Packs

FC 301 - Mains: 200-240V (T2)
FC 301
P
m (HO)
T2
[kW]
PK25
0.25
PK37
0.37
PK55
0.55
PK75
0.75
P1K1
1.1
P1K5
1.5
P2K2
2.2
P3K0
3
P3K7
3.7
FC 302 Mains: 200-240V (T2)
FC 302
P
m (HO)
T2
[kW]
PK25
0.25
PK37
0.37
PK55
0.55
PK75
0.75
P1K1
1.1
P1K5
1.5
P2K2
2.2
P3K0
3
P3K7
3.7
FC 301 Mains: 380-480V (T4)
FC 301
P
m (HO)
T4
[kW]
PK37
0.37
PK55
0.55
PK75
0.75
P1K1
1.1
P1K5
1.5
P2K2
2.2
P3K0
3
P4K0
4
P5K5
5.5
P7K5
7.5
P11K
11
P15K
15
FC 300 Design Guide
R
R
min
br, nom
[Ω]
[Ω]
368
408
248
276
330/100 or 310/200
166
185
220/100 or 210/200
121
135
150/100 or 150/200
81.0
91.4
100/100 or 100/200
58.5
66.2
40.2
44.6
29.1
32.4
22.5
25.9
R
R
min
br. nom
[Ω]
[Ω]
382
467
279
315
330/100 or 310/200
189
211
220/100 or 210/200
130
154
150/100 or 150/200
81.0
104.4
100/100 or 100/200
58.5
75.7
45.0
51.0
31.5
37.0
22.5
29.6
R
R
min
br. nom
[Ω]
[Ω]
620
1098
620
739
485
539
620/100 or 620/200
329
366
430/100 or 430/200
240.0
266.7
161.0
179.7
117.0
130.3
150/200 or 300/200
87
97
63
69
45
50
34.9
38.8
25.3
28.1
®
MG.33.BD.02 - VLT
is a registered Danfoss trademark
Flatpack IP65 for horizontal conveyors
Rrec per item
Duty Cycle
%
[Ω / W]
430/100
40
27 or 55
20 or 37
14 or 27
10 or 19
72/200
14
50/200
10
35/200 or 72/200
7 14
60/200
11
Flatpack IP65 for horizontal conveyors
Rrec per item
Duty Cycle
%
[Ω / W]
430/100
40
27 or 55
20 or 37
14 or 27
10 or 19
72/200
14
50/200
10
35/200 or 72/200
7 or 14
60/200
11
Flatpack IP65 for horizontal conveyors
Rrec per item
Duty Cycle
[Ω / W]
%
830/100
30
830/100
20
14 or 27
10 or 20
310/200
14
210/200
10
7 or 14
240/200
10
160/200
8
130/200
6
80/240
5
72/240
4
Order no.
175Uxxxx
1002
1003 or 0984
1004 or 0987
1005 or 0989
5
1006 or 0991
0992
0993
0994 or 2 x 0992
2 x 0996
Order no.
175Uxxxx
1002
1003 or 0984
1004 or 0987
1005 or 0989
1006 or 0991
0992
0993
0994 or 2 x 0992
2 x 0996
Order no.
175Uxxxx
1000
1000
1001 or 0982
1002 or 0983
0984
0987
0989 or 2 x 0985
2 x 0986
2 x 0988
2 x 0990
2 x 0090
2 x 0091
111
5