Mechanical Installation - ...
Illustration 7.3 Recommended Lifting Method, Frame Sizes F3,
F4, F11, F12 and F13
7
7
Illustration 7.4 Recommended Lifting Method, Frame Sizes F8
NOTE
The plinth is provided in the same packaging as the
frequency converter but is not attached to frame sizes F1-
F4 during shipment. The plinth is required to allow airflow
to the drive to provide proper cooling. The F frames
should be positioned on top of the plinth in the final
installation location. The angle from the top of the drive to
the lifting cable should be 60°C or greater.
In addition to the drawings above a spreader bar is an
acceptable way to lift the F Frame.
122
FC 300 Design Guide
®
MG.33.BD.02 - VLT
is a registered Danfoss trademark