FC 300 Selection
Mains Supply 3 x 525- 690V AC
FC 302
High/ Normal Load*
Typical Shaft output at 550V [kW]
Typical Shaft output at 575V [HP]
Typical Shaft output at 690V [kW]
Enclosure IP21
Enclosure IP54
Enclosure IP00
Output current
Continuous
(at 550V) [A]
Intermittent (60 sec overload)
(at 550V) [A]
Continuous
(at 575/ 690V) [A]
Intermittent (60 sec overload)
(at 575/690V) [A]
Continuous KVA
(at 550V) [KVA]
Continuous KVA
(at 575V) [KVA]
Continuous KVA
(at 690V) [KVA]
Max. input current
Continuous
(at 550V ) [A]
Continuous
(at 575V) [A]
Continuous
(at 690V) [A]
Max. cable size, mains, motor and
load share [mm
Max. cable size, brake [mm
(AWG)]
Max. external mains fuses [A]
Estimated power loss
at 600V [W]
Estimated power loss
at 690V [W]
Weight,
enclosure IP21, IP54 [kg]
Weight,
enclosure IP00 [kg]
Efficiency
Output frequency
Heatsink overtemp. trip
Power card ambient trip
* High overload = 160% torque during 60 sec., Normal overload = 110% torque during 60 sec.
FC 300 Design Guide
HO
315
400
400
429
644
410
615
409
408
490
413
395
395
4x240 (4x500 mcm)
2
(AWG)]
2
(2 x 350 mcm)
1
4478
4)
4605
4)
4)
®
MG.33.BD.02 - VLT
is a registered Danfoss trademark
P400
P500
NO
HO
400
400
500
500
500
500
E1
E1
E1
E1
E2
E2
523
523
575
785
500
500
550
750
498
498
498
498
598
598
504
504
482
482
482
482
4x240 (4x500 mcm)
2 x 185
2 x 185
(2 x 350 mcm)
700
900
5623
6153
5794
6328
263
272
221
236
0.98
0 - 500Hz
110°C
75°C
P560
NO
HO
NO
450
450
500
600
600
650
560
560
630
E1
E1
E2
596
596
630
656
894
693
570
570
630
627
855
693
568
568
600
568
568
627
681
681
753
574
574
607
549
549
607
549
549
607
4x240 (4x500 mcm)
2 x 185
(2 x 350 mcm)
900
7018
7007
7793
7221
7201
8017
313
277
79
4
4