FC 300 Selection
Mains Supply 3 x 525- 690V AC
FC 302
High/ Normal Load*
Typical Shaft output at
550V [kW]
Typical Shaft output at
575V [HP]
Typical Shaft output at
690V [kW]
Enclosure IP21, 55
Output current
Continuous
(3 x 525-550V) [A]
Intermittent (60 sec
overload)
(3 x 525-550V) [A]
Continuous
(3 x 551-690V) [A]
Intermittent (60 sec
overload)
(3 x 551-690V) [A]
Continuous KVA
(at 550V) [KVA]
Continuous KVA
(at 575V) [KVA]
Continuous KVA
(at 690V) [KVA]
Max. input current
Continuous
(at 550V) [A]
Continuous
(at 575V) [A]
Additional specifications
Max. cable cross section
2
(mains and motor) [mm
(AWG)]
Max. cable cross section
(load share and brake)
[mm
2
(AWG)]
Max cable size with mains
2
2)
disconnect [mm
(AWG)]
Estimated power loss
4)
at rated max. load [W]
Weight,
enclosure IP21, IP55 [kg]
4)
Efficiency
For fuse ratings, see 8.3.1 Fuses
1) High overload = 160% torque during 60 sec., Normal overload = 110% torque during 60 sec.
2) American Wire Gauge.
3) Measured using 5 m screened motor cables at rated load and rated frequency.
4) The typical power loss is at nominal load conditions and expected to be within +/-15% (tolerence relates to variety in voltage and
cable conditions).
Values are based on a typical motor efficiency (eff2/eff3 border line). Motors with lower efficiency will also add to the power loss in the
frequency converter and opposite.
If the switching frequency is increased compared to the default setting, the power losses may rise significantly.
LCP and typical control card power consumptions are included. Further options and customer load may add up to 30W to the losses.
(Though typical only 4W extra for a fully loaded control card, or options for slot A or slot B, each).
Although measurements are made with state of the art equipment, some measurement inaccuracy must be allowed for (+/-5%).
5) The three values for the max. cable cross section are for single core, flexible wire and flexible wire with sleeve, respectively.
FC 300 Design Guide
P30K
P37K
HO
NO
HO
22
30
30
30
40
40
30
37
37
C2
C2
36
43
43
54
47.3
64.5
34
41
41
51
45.1
61.5
34.3
41.0
41.0
33.9
40.8
40.8
40.6
49.0
49.0
36
49
49
54
53.9
72
95, 70, 70
(3/0, 2/0, 2/0)
480
592
0.98
0.98
®
MG.33.BD.02 - VLT
is a registered Danfoss trademark
P45K
NO
HO
NO
HO
37
37
45
45
50
50
60
60
45
45
55
55
C2
54
54
65
65
59.4
81
71.5
97.5
52
52
62
62
57.2
78
68.2
93
51.4
51.4
61.9
61.9
51.8
51.8
61.7
61.7
62.1
62.1
74.1
74.1
59
59
71
71
64.9
87
78.1
105
150 (300MCM)
95 (3/0)
185, 150, 120
(350MCM, 300MCM,
720
65
0.98
P55K
P75K
NO
HO
NO
55
55
75
75
75
100
75
75
90
C2
C2
87
87
105
95.7
130.5
115.5
83
83
100
91.3
124.5
110
82.9
82.9
100.0
82.7
82.7
99.6
99.2
99.2
119.5
87
87
99
95.7
129
108.9
-
4/0)
880
1200
0.98
0.98
75
4
4