Danfoss VLT AutomationDrive Design Manual page 66

Hide thumbs Also See for VLT AutomationDrive:
Table of Contents

Advertisement

FC 300 Selection
Mains Supply 3 x 380 - 500V AC (FC 302), 3 x 380 - 480V AC (FC 301)
FC 301/FC 302
High/ Normal Load
1)
Typical Shaft output [kW]
Enclosure IP20
Enclosure IP21
Enclosure IP55, 66
Output current
Continuous
(3 x 380-440V) [A]
Intermittent (60 sec.
overload)
(3 x 380-440V) [A]
Continuous
(3 x 441-500V) [A]
Intermittent (60 sec
overload)
(3 x 441-500V) [A]
Continuous kVA
(400V AC) [kVA]
Continuous kVA
(460V AC) [kVA]
Max. input current
Continuous
(3 x 380-440V) [A]
Intermittent (60 sec
overload)
(3 x 380-440V) [A]
Continuous
(3 x 441-500V) [A]
Intermittent (60 sec
overload)
(3 x 441-500V) [A]
Additional specifications
IP20 max. cable cross-
section
5)
(mains and
motor)
IP20 max. cable cross-
section
5)
(brake and load
sharing)
IP21, 55, 66 max. cable
5)
cross-section
(mains,
2
2)
motor) [mm
(AWG)]
IP21, 55, 66 max. cable
5)
cross-section
(brake, load
2
2)
sharing) [mm
(AWG)]
Max cable size with mains
disconnect [mm
2
(AWG)]
Estimated power loss
at rated max. load [W]
4)
Weight,
enclosure IP21, IP55, 66
[kg]
4)
Efficiency
For fuse ratings, see 8.3.1 Fuses
1) High overload = 160% torque during 60 sec., Normal overload = 110% torque during 60 sec.
2) American Wire Gauge.
3) Measured using 5 m screened motor cables at rated load and rated frequency.
4) The typical power loss is at nominal load conditions and expected to be within +/-15% (tolerence relates to variety in voltage and
cable conditions).
Values are based on a typical motor efficiency (eff2/eff3 border line). Motors with lower efficiency will also add to the power loss in the
frequency converter and opposite.
If the switching frequency is increased compared to the default setting, the power losses may rise significantly.
LCP and typical control card power consumptions are included. Further options and customer load may add up to 30W to the losses.
(Though typical only 4W extra for a fully loaded control card, or options for slot A or slot B, each).
Although measurements are made with state of the art equipment, some measurement inaccuracy must be allowed for (+/-5%).
5) The three values for the max. cable cross section are for single core, flexible wire and flexible wire with sleeve, respectively.
FC 300 Design Guide
P30K
HO
NO
HO
30
37
37
B4
C1
C1
61
73
73
91.5
80.3
110
52
65
65
78
71.5
97.5
42.3
50.6
50.6
51.8
55
66
66
82.5
72.6
99
47
59
59
70.5
64.9
88.5
35 (2)
35 (2)
50 (1)
50 (1)
50, 35, 35
2)
(1, 2, 2)
570
698
697
45
0.98
®
MG.33.BD.02 - VLT
is a registered Danfoss trademark
P37K
P45K
NO
HO
NO
45
45
55
C3
C3
C1
C1
C1
C1
90
90
106
99
135
117
80
80
105
88
120
116
62.4
62.4
73.4
63.7
83.7
82
82
96
90.2
123
106
73
73
95
80.3
110
105
50 (1)
50 (1)
50 (1)
50 (1)
50 (1)
50 (1)
50 (1)
50 (1)
843
891
1083
45
45
0.98
0.98
P55K
P75K
HO
NO
HO
NO
55
75
75
90
C4
C4
C2
C2
C2
C2
106
147
147
177
159
162
221
195
105
130
130
160
158
143
195
176
73.4
102
102
123
104
128
96
133
133
161
144
146
200
177
95
118
118
145
143
130
177
160
150 (300mcm)
150 (300mcm)
95 (4/0)
95 (4/0)
150 (300MCM)
150 (300MCM)
95 (3/0)
95 (3/0)
185, 150, 120
95, 70, 70
(350MCM, 300MCM,
(3/0, 2/0, 2/0)
4/0)
1022
1384
1232
1474
65
65
0.98
0.99
4
4
65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt fc 300