Advertisement

Debugger gdb (7)
Status and Error Messages
Error messages
Cannot display clock counter.
Now Timer break mode is on.
Please timer break mode off.
Cannot display clock counter.
Time measurement should use continue
or until command.
Cannot measure clock timer.
Cannot open file(file).
Cannot open ICD17 usb driver.
Cannot set hard pc break any more.
Cannot set soft pc break any more.
Cannot set timer.
Timer Conditions: 1<=Timer<=300000
Cannot write file.
Clock timer overflow.
Communication error(bcc).
Communication system error(#).
Copy end address max(0x#) overflow.
Copy start address max(0x#) overflow.
Coverage Window is already opened.
CPU is running.
Erase entry address max(0x#) overflow.
Flash memory end address max(0x#)
overflow.
Flash memory start address max(0x#)
overflow.
ICD17 is busy(#).
Initialization error of ICD17.
Invalid ID error(0x#).
Invalid parameter file(#: file).
The execution counter value cannot be displayed when
the lapse of time break is enabled. Disable the lapse
of time break before execution times can be measured.
The execution counter value cannot be displayed if
the continue or until command has not been
executed.
The program execution time cannot be measured as
it is too short.
The system cannot open the file.
The system failed to open the USB driver.
The number of hardware PC breakpoints set exceeds
the limit (1).
The number of software PC breakpoints set exceeds
the limit (200).
Cannot set a lapse of time break as the specified
time exceeds the valid range.
The system cannot write to the file.
The clock measurement timer has overflowed.
A BCC error was found in the messages received
from the ICD.
The connection was unexpectedly terminated during
communication with the ICD.
The end address of the source to be copied exceeds
the upper limit (0xffffff).
The start address of the source to be copied exceeds
the upper limit (0xffffff).
A coverage window is open.
Cannot accept a command while the CPU is running.
The flash erase routine address exceeds the upper
limit (0xffffff).
The flash memory end address exceeds the upper
limit (0xffffff).
The flash memory start address exceeds the upper
limit (0xffffff).
The ICD side is busy.
The system failed to initialize the target.
The gdb has transmit an invalid ID number.
(Internal error)
The parameter file contains an error.
Error messages
Invalid parameter file,
start address > end address(#: file).
It has not connected with a target.
It is not c17 architecture ELF file.
Load end address max(0x#) overflow.
Load max address(0x#) overflow.
Load motorola file format error.(file)
Load size limit(0x#) overflow.
Load start address max(0x#) overflow.
Profiler Window is already opened.
Receiving message is inaccurate.
Specification is required in the device for There is an insufficient number of device names from
connecting.
Target down.
There is no argument given to this
command.
Timeout error #(ICD17 -> host).
Too much event(#).
Transmitting failure(#).
USB communication error(host->ICD17). The system failed in USB transmission to the ICD.
USB communication error(ICD17->host). The system failed in USB receiving from ICD.
Write entry address max(0x#) overflow.
Development Tools
The address range set in the parameter file is invalid,
as the number used as the start address is greater
than that used as the end address.
The ICD cannot be connected to the target.
The file specified with the file command is not an
elf format file supported in S5U1C17001C.
The end address of the program to be written to flash
memory exceeds the upper limit (0xffffff).
The addresses to be loaded exceed the maximum
value.
The specified Motorola file contains a format error.
The size of the specified file exceeds the upper limit.
¥ Flash write/erase program
8K bytes - 1 byte (0x1fff)
¥ Write data for flash memory
3M bytes - 1 byte (0x2fffff)
¥ Firmware
8M bytes - 1 byte (0x7fffff)
The start address of the program to be written to
flash memory exceeds the upper limit (0xffffff).
A profiler window is open.
A message exceeding the maximum size was
received during communication with the ICD.
which to select the ICD in the target command.
A communication error has occurred between the
ICD and the target.
The system failed to disconnect the target.
In communication with the ICD, a receive operation
timed out during the wait for data from the ICD.
The number of events specified with the c17 int_
load (event file read) command exceeds the upper
limit (256).
NAK was received from the ICD during
communication with the ICD.
The address of the flash write routine exceeds the
upper limit (0xffffff).