Status And Error Messages; Status Messages; Error Messages - Epson S5U1C17001C Manual

Cmos 16-bit single chip microcomputer, c compiler package for s1c17 family
Hide thumbs Also See for S5U1C17001C:
Table of Contents

Advertisement

10 DEBUggEr

10.10 Status and Error Messages

10.10.1 Status Messages

When the target program breaks, one of the following messages is displayed, indicating the cause of the break
immediately before entering the command input wait state.
Message
Breakpoint #, function at file : line
Break by accessing no map.
Break by writing ROM area.
Break by stack overflow.
Illegal instruction.
Illegal delayed instruction.
Break by key break.
Break by key break. Program received signal
SIGINT, Interrupt.

10.10.2 Error Messages

Message
· · · gdb : unrecognized option ' option '
A setup of a serial port was not completed.
Address is 24bit over.
Address(0x # ) is ext or delayed instruction.
C17 command error, command is not supported at
present mode.
C17 command error, command is too long.
C17 command error, invalid command.
C17 command error, invalid parameter.
C17 command error, number of parameter.
C17 command error, start address > end address.
C17 command error, start cycle < end cycle.
Cannot access memory.
Cannot allocate memory.
Cannot clear hard pc break(0x # ).
Cannot clear soft pc break(0x # ).
Cannot display clock counter.
Now Timer break mode is on.
Please timer break mode off.
Cannot display clock counter.
Time measurement should use continue or until
command.
Cannot measure clock timer.
Cannot open file( file ).
Cannot open ICD17 usb driver.
Cannot set hard pc break any more.
Cannot set soft pc break any more.
10-162
Table 10.10.1.1 Status messages
Made to break at a set breakpoint
Made to break by accessing unmapped area in simulator mode
Made to break by accessing read-only area in simulator mode
Made to break by stack overflow in simulator mode
Made to break by executing invalid instruction in simulator mode
Made to break by executing invalid delayed instruction in
simulator mode
Forcibly made to break by [Stop] button (in simulator mode)
Forcibly made to break by [Stop] button (in ICD Mini mode)
Table 10.10.2.1 Error messages (in alphabetical order)
An illegal startup option is specified.
An ICD mode not supported in gdb is specified.
The specified address is out of the 24-bit range. The maximum
S1C17 address size is 24 bits (0xffffff).
The specified address cannot be set due to an ext or delayed
instruction.
The input command cannot be executed in the current connect
mode (ICD Mini or simulator mode).
The input command exceeds 256 characters in length.
The command is erroneous.
The command is specified with an invalid parameter.
The number of command parameters is incorrect.
The specified start address is greater than the end address.
The specified start cycle is greater than the end cycle.
The specified address cannot be accessed.
The necessary size of memory area as specified by a parameter
could not be reserved.
The specified hardware PC break address is invalid; no
breakpoints are set there.
The specified software PC break address is invalid; no
breakpoints are set there.
The execution counter value cannot be displayed when the
lapse of time break is enabled. Disable the lapse of time break
before execution times can be measured.
The execution counter value cannot be displayed if the con-
tinue or until command has not been executed.
The program execution time cannot be measured as it is too
short.
Cannot open the file.
Failed to open the USB drive.
The number of hardware PC breakpoints set exceeds the limit
(one location only).
The number of software PC breakpoints set exceeds the limit (up
to 200).
EPSOn
Description
Description
(C COMPilEr PaCkagE fOr S1C17 faMily) (Ver. 1.5.0)
S5U1C17001C ManUal

Advertisement

Table of Contents
loading

Table of Contents