3. Diagnosis
3.3

Diagnosis with PROFIBUS-DP

3.3.1 Diagnostic words

Festo P.BE-CP-FB13-E-EN en 0112e
The CP system supports diagnostic possibilities via the PRO-
FIBUS in accordance with EN 50170 (DIN 19245) (The device-
specific diagnosis is supported).
Please note
The identifier-related or channel-related diagnosis listed in
EN 50170 (DIN 19245) is not supported.
The following error states of the CP system are grouped into
diagnostic words and passed on to the programmer.
Load voltage failure on the output modules
Short circuit/overload at the output modules
Interruption in CP connection on various CP modules
Additional error messages (DIL switch 2 = ON):
Load voltage failure on the CP connection
Drop below tolerance in voltage for CP valves ( < 20.4 V)