Allen-Bradley Powermonitor 3000 User Manual page 177

Table of Contents

Advertisement

Table A.1 Summary of Powermonitor 3000 Data Tables for all Communications Options
Data Table Name and Description
Transient Analysis Metering Results
Transient Capture Clear/Read-Back Data Select
Transient Capture Results
Advanced Metering Configuration
Harmonic Results; Odd Harmonics 43 to 63
Harmonic Results; Even Harmonics 42 to 62
Event Log Text
Catalog Number and WIN
Network Demand Sync and Time Configuration
(1)
Controller Command
Daylight Saving Time Configuration
Time of Use Register Configuration
Time of Use Records – Real Energy and Demand R
Time of Use Records – Reactive Energy and
Demand
Time of Use Records – Apparent Energy and
Demand
(1) Supported only on 1404-xxxxx-ENT-xx Series B modules.
(2) Data is most commonly read from this table using the Indexed read method. Refer to Indexed reads of large data .
(3) Powermonitor 3000 starts with file 9 to avoid any data-type incompatibility with SLC file numbers 1 through 8, which are of a fixed data type.
(4) This is a reply to a PCCC diagnostic status request, used by RSWho to display text and an icon for the product.
(5) Remote I/O tables and the default DeviceNet input channel are PLC/SLC compatible, but if the user reconfigures the DeviceNet input channel (Instance 1), it may or may
not be PLC/SLC compatible (depending on the number of parameters configured).
(6) Basic device configuration data table size is 8 elements for the M4 and M5, and 9 elements for the M6 and M8.
(7) The size of the Trend log results table is 28 elements for DeviceNet and 44 elements for all other communication protocols.
(8) The size of the Event log results table is 14 elements for M4/M5, 17 elements for M6 and 18 elements for the M8.
(9) The User-configured table results table is populated from the bottom up with the number of parameters the user has configured. The DeviceNet table must contain 14
elements or less to remain PLC/SLC compatible.
(10) Harmonic results; THD, crest factor, and more data table size is 18 elements for the M4 and M5 and 20 elements for the M6 and M8.
(11) The Oscillograph results and Transient capture results tables are 29 elements for DeviceNet and 59 elements for all other communication protocols.
(12) The I/O table is user configurable for DeviceNet and EtherNet/IP only (Instance 1).
Allen-Bradley HMIs
R
F44
32
R/W
N45
17
R
N46
60
R/W
N47
19
R
F48
45
R
F49
46
R/W
N50
37
R
N51
50
R/W
N52
-
(1)
W
N53
-
R/W
N54
47
R/W
N55
49
F56
51
R
F57
52
R
F58
53
Powermonitor 3000 Data Tables
54
-
14
55,56
-
13
57
-
(11)
29 or 59
58,59
-
10
60
-
14
61
-
14
62,63
-
23
64
32301
29
65, 66
41901
20
67
42601
1
68,69
42100
10
70,71
42200
10
72
32300
12
73
32400
12
74
32500
12
Publication 1404-UM001D-EN-E - October 2004
A-3
Applies to
Refer to
Table A.44
Table A.45
Table A.46
Table A.47
Table A.48
Table A.49
Table A.50
• •
Table A.51
• •
Table A.52
• •
Table A.53
• •
Table A.54
• •
Table A.55
• •
Table A.56
• •
Table A.57
• •
Table A.58

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1404-m41404-m61404-m51404-m8

Table of Contents