Terms - Mitsubishi Electric NZ2GF2S-60IOLD8 User Manual

Cc-link ie field network remote io-link module
Table of Contents

Advertisement

TERMS

Unless otherwise specified, this manual uses the following terms.
Term
CC-Link IE Field Network
CommDTM(Communication DTM)
CPU module
CQ input signal
CQ output signal
Cyclic transmission
Data link
Dedicated instruction
Device DTM
DI signal
Disconnection
DTM catalog
DTM(Device Type Manager)
Engineering tool
FDC
FDT frame application
FDT(Field Device Tool)
Global label
Intelligent device station
IO-Link device
IO-Link master
IO-Link mode
IO-Link module
IODD DTM Configurator
IODD(IO-Link Device Description)
ISDU
Label
Link device
Link special register (SW)
Link special relay (SB)
Local station
M_CommDTM-IOLink
Master station
Master/local module
MELSOFT FieldDeviceConfigurator
Module label
Description
A high-speed and large-capacity open field network that is based on Ethernet (1000BASE-T)
A software module used to configure the communication setting required for communications between a personal
computer and field devices via the IO-Link master.
A generic term for the MELSEC iQ-R series CPU module, MELSEC-Q series CPU module, and MELSEC-L series CPU
module
An external input signal input by the IO-Link master via the CQ line when the operation mode is the SIO (sink input)
mode
An external output signal output by the IO-Link master via the CQ line when the operation mode is the SIO (source
output) mode
A function by which data are periodically exchanged among master stations and other stations on the same system
using link devices
A generic term for cyclic transmission and transient transmission
An instruction for using the functions of a module
A software module used to configure the parameter settings of field devices or monitor field devices.
An external input signal input by the IO-Link master via the DI line when the operation mode is the IO-Link (sink input)
mode
A process of stopping data link if a data link error occurs
By registering the M_CommDTM-IOLink, the DTM catalog displays a list of available DTMs.
A software module used to configure the communication settings, set parameters of field devices, or monitor field
devices when an FDT frame application is used.
Another term for the software package for the MELSEC programmable controllers
An abbreviation for the MELSOFT FieldDeviceConfigurator
A generic term for applications to use a DTM. An FDT frame application complies with the FDT/DTM open standard
Software standard specifications for management, maintenance, adjustment, and development of field devices
A label that is valid for all the program data when multiple program data are created in the project.
There are two types of global label: a module specific label (module label), which is generated automatically by GX
Works3, and an optional label, which can be created for any specified device.
A station that exchanges I/O signals (bit data) and I/O data (word data) with another station by cyclic transmission. This
station can perform transient transmission as well. This station responds to a transient transmission request from
another station and also issues a transient transmission request to another station.
An external device that supports IO-Link
Performs communications with the IO-Link sensor and actuator in the IO-Link module
A generic term for the IO-Link (standard) mode and IO-Link (sink input) mode
An abbreviation for the CC-Link IE Field Network remote IO-Link module
A software program that operates the IODD file (device description file of IO-Link) as the Device DTM.
This description consists of the XML file containing the IO-Link device information and the image file in the png format.
This description is supplied from a manufacturer of an IO-Link device.
Data read from or written to parameters of IO-Link devices
A label that represents a device in a given character string
A device (RX, RY, RWr, or RWw) in a module on CC-Link IE Field Network
Information that indicates the operating status and data link status of a module on CC-Link IE Field Network in units of
16 bits (1 word)
Bit data that indicates the operating status and data link status of a module on CC-Link IE Field Network
A station that performs cyclic transmission and transient transmission with the master station and other local stations.
CommDTM that supports communications with the IO-Link device via the IO-Link module.
A station that controls the entire network. This station can perform cyclic transmission and transient transmission with all
stations. Only one master station can be used in a network.
An abbreviation for the CC-Link IE Field Network master/local module
Configuration Tool, which is developed by Mitsubishi Electric Corporation.
MELSOFT FieldDeviceConfigurator complies with the FDT/DTM open standard and is used for parameter settings,
maintenance, and adjustment of field devices as an FDT frame application.
A label that represents one of memory areas (I/O signals and buffer memory areas) specific to each module in a given
character string. For the module used, GX Works3 automatically generates this label, which can be used as a global
label.
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents