Mitsubishi Electric NZ2GF2S-60IOLD8 User Manual page 183

Cc-link ie field network remote io-link module
Table of Contents

Advertisement

Event history clear completed
■Remote buffer memory address
Address
2D01H
■Description
The clear completion status of the event history stored in the IO-Link module is shown.
Stored value
0H
1H
■Operation of Event history clear
When the event history clear is completed, Event history clear completed (address: 2D01H) is turned to Completed (1).
For the timing of Not completed (0)  Completed (1)  Not completed (0), refer to the following.
Page 180 Event history clear command
Operating condition setting request flag
■Remote buffer memory address
Address
2D07H
■Description
This flag is used for reflecting parameters after writing parameter data to the remote buffer memory.
b15
b14
b13
b12
0 (fixed)
(1) ON: Request, OFF: Not performed
b11
b10
b9
b8
Name
Event history clear completed
Event history clear completed
Not completed
Completed
Name
Operating condition setting request flag
b7
b6
b5
b4
Appendix 3 Remote Buffer Memory
b3
b2
b1
b0
(1)