Mitsubishi Electric NZ2GF2S-60IOLD8 User Manual page 173

Cc-link ie field network remote io-link module
Table of Contents

Advertisement

Event acquisition setting
■Remote buffer memory address
Address
1708H
1808H
1908H
1A08H
1B08H
1C08H
1D08H
1E08H
■Description
The event acquisition function for the IO-Link device of each channel is set.
b15
b14
b13
b12
0 (fixed)
(1) Notifications
(2) Warnings
• Notifications
Setting value
0H (default value)
1H
• Warnings
Setting value
0H
1H (default value)
2H
This setting is enabled only when the operation mode is the IO-Link mode.
■Enabling the setting
Turn on and off Operating condition setting request flag (address: 2D07H) to enable the setting.
b11
b10
b9
b8
Name
CH1 Event acquisition setting
CH2 Event acquisition setting
CH3 Event acquisition setting
CH4 Event acquisition setting
CH5 Event acquisition setting
CH6 Event acquisition setting
CH7 Event acquisition setting
CH8 Event acquisition setting
b7
b6
b5
b4
Notifications
Do not retrieve
Retrieve as events
Warnings
Do not retrieve
Retrieve as events
Retrieve as errors
Appendix 3 Remote Buffer Memory
b3
b2
b1
b0
(2)
(1)
APPX
171
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents