Device replacement status
■Remote buffer memory address
Address
299DH
■Description
The device replacement status of each channel is stored.
The following occurs when Device replacement status (address: 299DH) is on.
• Disconnections will not be detected in the corresponding channel.
• Input to and output from IO-Link devices is disabled in the IO-Link mode.
• Input to and output from SIO devices is turned off in the SIO mode.
Using Device replacement status (address: 299DH), the corresponding channel turns on under the following circumstances.
• When the corresponding channel turns on using Device replacement flag (address: 36CCH) ( Page 185 Device
replacement flag)
• When the corresponding channel was set using "Start Device Changeout" of "Command Execution of Slave Station" in the
engineering tool ( Page 101 Device replacement start procedure)
Using Device replacement status (address: 299DH), the corresponding channel turns off under the following circumstances.
• When the corresponding channel turns off using Device replacement flag (address: 36CCH) ( Page 185 Device
replacement flag)
• When the corresponding channel was set using "Device Changeout Complete" of "Command Execution of Slave Station" in
the engineering tool ( Page 102 Device replacement completion procedure)
b15
b14
b13
b12
0 (fixed)
CH ON: Device replacement permitted, OFF: Device replacement prohibited
Number of output ON times integration value
■Remote buffer memory address
Address
299EH, 299FH
29A0H, 29A1H
29A2H, 29A3H
29A4H, 29A5H
29A6H, 29A7H
29A8H, 29A9H
29AAH, 29ABH
29ACH, 29ADH
■Description
Integration values of the number of output ON times integration function for each channel are saved as 32-bit signed binary
data. ( Page 87 Number of output ON times integration function)
Values read from the non-volatile memory when the CPU module is powered on or the remote reset is executed are stored in
the number of output ON times integration value.
This setting is enabled only when the operation mode is the SIO (source output) mode.
b11
b10
b9
b8
Name
Device replacement status
b7
b6
b5
b4
CH8
CH7
CH6
CH5
Name
CH1 Number of output ON times integration value
CH2 Number of output ON times integration value
CH3 Number of output ON times integration value
CH4 Number of output ON times integration value
CH5 Number of output ON times integration value
CH6 Number of output ON times integration value
CH7 Number of output ON times integration value
CH8 Number of output ON times integration value
Appendix 3 Remote Buffer Memory
b3
b2
b1
b0
CH4
CH3
CH2
CH1
APPX