Mitsubishi Electric NZ2GF2S-60IOLD8 User Manual page 132

Cc-link ie field network remote io-link module
Table of Contents

Advertisement

3.
Set "Method selection" to "Read Current Errors" and click the [Execute] button. Follow the instructions displayed in the
window, and the current error of the IO-Link module will be displayed in "Execution Result".
Displayed items
Item
Error Information and Troubleshooting Procedure
Date of Occurrence (Western format)
Date of Occurrence (Month/Day)
Date of Occurrence (Hour/Minute)
Date of Occurrence (Second/Not Used)
Error Code Information 1
Error Code Information 3
*1 "Date of Occurrence" of the current error is based on the clock information acquired from the CPU module of the master station. If an
error occurs without data link establishment with the master station, the error time is not recorded because the IO-Link module does not
have clock information used as the reference.
• The current error can be read from a program. Refer to the remote buffer memory address where the error
history is stored. ( Page 178 Current error data)
• Up to 16 current errors (15 minor/moderate errors and one major error) are recorded. When 15 minor and
moderate errors have occurred, new minor and moderate errors that occur are held in the IO-Link module.
• If the same error occurs continuously, only the error that occurred first is stored.
• Even after the power of the module is turned off and on, the error history remains.
• To initialize the current error, set "Method selection" to "Clear Current Error" in the "Command Execution of
Slave Station" window and click the [Execute] button after eliminating the cause of the error. Although the
error can be cleared temporarily even if "Clear Current Error" is executed without eliminating the error
cause, the error will be detected again and stored in as current errors.
11 TROUBLESHOOTING
130
11.5 Checking for the Error Codes and the Warning Codes
*1
*1
*1
*1
Contents
The action for the error is displayed.
The date and hour of error occurrence is displayed. (When the tens place of
month, hour, and second is 0, 0 is omitted.)
Values of Error code details 1 to 3 of the remote buffer memory are stored
when an error occurs.