Item
IO-Link (sink input)
Number of channels
mode
Rated input current
Input response time
ON voltage/ON current
OFF voltage/OFF current
SIO (sink input) mode
Number of channels
Rated input current
Input response time
ON voltage/ON current
OFF voltage/OFF current
SIO (source output)
Number of channels
mode
Rated load current
Maximum inrush current
Leakage current at OFF
Maximum voltage drop at ON
IO-Link cable
Cable type
Cable length
Cable diameter
Communication cable
Module power supply
Voltage
Current
Protection function
Fuse
External power supply
Voltage
Current
Protection function
Fuse
Weight
*1 Only one wire can be connected to a terminal. Multiple wires cannot be connected to a terminal. Connecting two or more wires may
cause a poor contact.
*2 For details on the input response time, refer to the following.
Page 192 Processing Time
*3 Use cables suitable for the current value used.
*4 The time taken for data link establishment with the master station at power-on is not included.
*5 The module operation start time written is a rough standard. The time depends on the response performance and data storage size of
the IO-Link device. In addition, because the start processing is performed for each channel, it takes longer time to start operation of the
module as the number of channels of which operation mode is set to IO-Link mode increases.
NZ2GF2S-60IOLD8
8 channels max.
2.5mA TYP. (for 24VDC)
• 0ms
• 1ms
• 1.5ms
• 5ms
• 10ms (default value)
• 20ms
• 70ms
12VDC or more/2mA or more
6VDC or less/2mA or less
8 channels max.
2.4mA TYP. (for 24VDC)
*2
• 0ms
• 1ms
• 1.5ms
• 5ms
• 10ms (default value)
• 20ms
• 70ms
11VDC or more/2mA or more
6VDC or less/2mA or less
8 channels max.
200mA/point, 4A/common
650mA 100s or less
0.1mA or less
0.88V or less, 0.2mA
Unshielded
20m maximum
Core 0.2 to 1.5
An Ethernet cable that meets the 1000BASE-T standard:
Category 5e or higher (double shielded, STP), straight cable
24VDC (ripple rate: 5% or less)
(allowable voltage range 20.4 to 28.8VDC (24VDC -15 to +20%))
130mA (24VDC, all points ON)
None
None
24VDC (ripple rate: 5% or less)
(allowable voltage range 20.4 to 28.8VDC (24VDC -15 to +20%))
95mA or less (24VDC, all points ON)
None
None
0.24kg