Function combinations
The following shows a list of operations of the function combinations that deal with input process data.
Parameter setting
When "Number of Slicings" is 0
When "Number of Slicings" is 1 or
more
For details on the functions, refer to the following.
Page 74 Input data masking function
Page 76 Swap function
Page 78 Bit segment function
Setting method
Operating procedure
1.
Open the "CC IE Field Configuration" window.
[Navigation window]  [Parameter]  [Module Information]  [RJ71GF11-T2]  [Basic Settings]  [Network
Configuration Settings]
2.
Open the "Parameter Processing of Slave Station" window.
From the list of stations, select an IO-Link module  [CC IE Field Configuration]  [Online]  [Parameter Processing of
Slave Station].
3.
Set "Method selection" to "Write Parameters".
4.
For each channel, set "Operation Mode" to any of the following.
• 1: IO-Link(Standard)Mode
• 2: IO-Link(Sync Input)Mode
Window
Swap operation
Input process data that has been
swapped or not yet swapped is
stored in the remote register in
accordance with "Byte Position
Swap".
No operation.
Bit segment operation
No operation.
Input process data segmented is
stored in the remote register in
accordance with "Bit Slicing Setting".
Input data masking operation
Masking results for the process data
configuration defined in the IO-Link
device manual are stored in the
remote input in accordance with
"Input Data Mask". Data to be
masked is not affected by the swap or
bit segment operations.
7 FUNCTIONS
7.1 IO-Link Master Functions
7
65