A.12

Technical data: IDEC SmartRelay Power 24 V

IDEC SmartRelay Power 24 V is a primary.
A.13

Technical data: FL1F-RD1 (Text Display with Ethernet interfaces)

Mechanical data
Keyboard
Display
Power supply
Input voltage
Permissible range
Permissible mains frequency
Power consumption (Ethernet and
white backlight active)
12 VDC
24 VDC
24 VAC
Degree of protection
Communication port
Ethernet performance
Connection distance
LCD Display and Backlight
Backlight lifetime
Display lifetime
Mounting
Mounting hole dimensions (WxH)
Mounting conditions
1)
The backlight lifetime is when the final brightness is 50% of the original brightness.
2)
The display lifetime is calculated under ordinary operating and storage conditions: room temperature
(20 ± 8 °C), normal humidity below 65% relative humidity, and not in exposure to direct sunlight.
IDEC SmartRelay Manual
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
FL1F-RD1
Membrane keypad with 10 keys
FSTN-Graphic Display with 160 x 96 (columns x rows), LED
backlight (white/amber/red)
24 VAC/VDC
12 VDC
20.4 VAC to 26.4 VAC
10.2 VDC to 28.8 VDC
47Hz to 63 Hz
IP20 for FL1F-RD1 excluding front panel
IP65 for FL1F-RD1 front panel
Two Ethernet interfaces with 10/100 M full/half duplex data
transmission rate
Max. 30 m
20,000 hours
1)
2)
50,000 hours
(119 + 0.5 mm) x (78.5 + 0.5 mm)
Mount the FL1F-RD1 vertically on a flat surface of an IP 65
or Type 4x/12 enclosure.
A.12 Technical data: IDEC SmartRelay Power 24 V
Typ. 145 mA
Typ. 70 mA
Typ. 75 mA
Technical data