Parameter T
Note the defaults for parameter T in topic Time response (Page 124).
The actual value of another already-configured functions can provide the time for parameter
T. You can use the actual values of the following functions for the value of T:
Analog comparator (Page 183)(actual value Ax - Ay)
Analog trigger (Page 178)(actual value Ax)
Analog amplifier (Page 191)(actual value Ax)
Analog multiplexer (Page 209)(actual value AQ)
Analog ramp control (Page 212)(actual value AQ)
Analog Math (Page 224) (actual value AQ)
PI controller (Page 216)(actual value AQ)
Up/down counter (Page 168)(actual value Cnt)
Analog filter (Page 229) (actual value AQ)
Average value (Page 235) (actual value AQ)
Max/Min (Page 231) (actual value AQ)
On-delay (current time Ta)
Off-delay (Page 136)(current time Ta)
On-/off-delay (Page 138)(current time Ta)
Retentive on-delay (Page 140)(current time Ta)
Interval time-delay relay/Pulse output (Page 142)(current time Ta)
Edge-triggered interval time-delay relay (Page 144)(current time Ta)
Asynchronous pulse generator (Page 146)(current time Ta)
Stairwell light switch (Page 150)(current time Ta)
Dual-function switch (Page 152)(current time Ta)
Stopwatch (Page 166)(actual value AQ)
Frequency trigger (Page 175) (actual value Fre)
Select the required function by the block number. The timebase is configurable.
Valid ranges of the timebase, if T = parameter
Note the following characteristics of timebase values.
Timebase
s (seconds)
m (minutes)
h (hours)
IDEC SmartRelay Manual
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
max. value
min. resolution
99:99
10 ms
99:59
1s
99:59
1 min
IDEC SmartRelay functions
4.4 Special functions list - SF
Accuracy
+ 10 ms
+ 1 s
+ 1 min