Max/Min - IDEC SMARTRELAY User Manual

Hide thumbs Also See for SMARTRELAY:
Table of Contents

Advertisement

4.4.35

Max/Min

Short description
The Max/Min function records the maximum or minimum value of Ax.
Symbol in
IDEC SmartRelay
AI1 to AI8: 0 V to 10 V corresponds with 0 to 1000 (internal value).
IDEC SmartRelay Manual
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
iring
Description
En
A signal at input En (Enable) outputs an analog value
to A , depending on the settings of parameters ERst
and Mode.
S1
S1 functions only when the parameter Mode is set to 2.
If Mode is set to 2, a change in status from 0 to 1 at
input S1 (selector) outputs the maximum value to A .
If Mode is set to 2, a change in status from 1 to 0 at S1
outputs the minimum value to A .
Ax
Input Ax is one of the following analog signals:
Parameter
Mode:
Possible settings:
0, 1, 2, 3
Mode
Mode
Mode
Mode
Mode
ERst (Enable Reset):
Possible settings:
ERst
ERst
Retentivity:
/
R
Output A
The function issues a minimum, maximum, or current
value at A , depending on your configuration.
IDEC SmartRelay functions
4.4 Special functions list - SF
AI1 to AI8 ( )
AM1 to AM64
NAI1 to NAI32
A 1 to A 8
NA 1 to NA 16
Block number of a function with analog output
0: A
Min
1: A
Max
2 and S1 0 (low): A
2 and S1 1 (high): A
3: A
Actual value of Ax
0: disable reset
1: enable reset
no retentivity
the status is retentive
Min
Max
231